The low surgical site infection (SSI) and nosocomial infection rates at Stenum Hospital stem from a combination of its structural model as an elective specialty clinic, direct environmental and sterile processing controls, and strict adherence to German hospital hygiene standards.
Dedicated Elective Specialty Focus (“Clean Hospital” Advantage)
General acute-care hospitals maintain emergency departments, intensive care units treating septic patients, infectious disease wards, and internal medicine floors. These settings harbor opportunistic hospital-acquired pathogens, including multidrug-resistant organisms (MDROs) such as MRSA and VRE.
In contrast, Stenum Hospital operates purely as an elective orthopedic and motion-preservation specialty center. Because it does not admit polytrauma cases, acute septic emergencies, or general internal medicine patients, the baseline environmental bacterial load across its wards, corridors, and air pathways is inherently lower than in large multi-specialty medical centers.
On-Site Central Sterile Services Department (AEMP / ZSVA)
Stenum Hospital maintains its own dedicated sterilization and reprocessing unit (Aufbereitungseinheit für Medizinprodukte) with a direct physical link to the operating suites:
Elimination of Transport Contamination: Instruments do not need to be packaged and transported across external logistics networks or third-party sterilization hubs, minimizing transit degradation of sterile barriers.
Immediate Turnaround and Strict Quality Control: Every surgical set is cleaned, disinfected, inspected, and autoclaved on-site according to German Medical Devices Operator Ordinance (MPBetreibV) and DIN/ISO standards.
Traceability: Direct oversight allows surgical teams and hygiene officers to inspect instruments and implant sets immediately prior to surgery.
Preoperative Screening and Decolonization Protocols
Under guidelines set by Germany’s Commission for Hospital Hygiene and Infection Prevention (KRINKO) at the Robert Koch Institute (RKI), surgical specialty clinics implement routine pre-admission surveillance:
Pre-Admission Swabbing: Elective arthroplasty and spine patients undergo screening for nasal/skin carriage of MRSA and other resistant pathogens prior to or on admission.
Eradication/Decolonization: Carriers are placed on targeted decolonization protocols (such as mupirocin nasal ointment and chlorhexidine/octenidine antiseptic body washes) before entering the operating suite, significantly reducing endogenous bacterial shedding.
Intraoperative Environmental & Procedural Controls
Orthopedic implant procedures (such as total disc replacement or joint arthroplasty) carry high consequences if bacteria adhere to synthetic foreign materials:
Airflow Management: Operating theaters utilize specialized ventilation and clean-air filtration systems designed to channel filtered air downward over the sterile field, keeping particulate and microbial counts far below conventional room levels.
Standardized Perioperative Normothermia: Patient body temperature is actively maintained from induction through closure using pre-warmed blankets, convective warm-air systems, and warmed IV fluids. Preventing perioperative hypothermia preserves peripheral tissue perfusion and immune function, which directly lowers SSI risk.
Prophylactic Timing: IV antibiotic prophylaxis is administered in the anesthesia induction window (typically 30–60 minutes before incision) to achieve peak tissue concentration at the moment the skin barrier is broken.
High Surgical Volume and Standardized Pathways
Surgical site infection risk rises steeply as operating times increase. Because the surgical and nursing teams at Stenum perform standardized anterior retroperitoneal spine exposures, disc replacements, and joint arthroplasties on a daily basis:
Operative workflows are streamlined and rapid, minimizing the duration the surgical wound remains open to the environment.
Postoperative wound management, handled by certified wound managers and specialized nursing staff, follows strict standardized change protocols on the wards.
Continuous tracking via internal incident reporting (CIRS) and active infection surveillance continuously flags variations in wound healing before complications escalate.
- Stenum Hospital International Patient Portal: Preliminary remote MRI evaluations, international intake protocols, and surgical technology overviews for European and overseas patients
Stenum Hospital
Medically Reviewed By
Dr. med. Karsten Ritter-Lang M.D.
Diploma of medicine (Institut of Immunology Charité)
1988 – 1991
Doctorade of medicine (Institut of Immunology Charité)
Senior consultant of spinal surgery in two hospitals (DRK Berlin Westend and Stenum Hospital) and private practice in Potsdam,ENDOCERT Certified awarded the title and certification of Specialist for Trauma Surgery (Facharzt für Unfallchirurgie) in 2009
Schedule Surgery Now
Go to
Investigated multi-axis kinematics and coupled physiological motion of viscoelastic artificial cervical discs (M6-C) compared to intact segments.
Citation: Patwardhan AG, Tzermiadianos MN, Tsitsopoulos PP, Voronov LI, Renner SM, Reo ML, Carandang G, Ritter-Lang K, Havey RM. Primary and coupled motions after cervical total disc replacement using a compressible six-degree-of-freedom prosthesis. European Spine Journal, 2012; 21(4): 618–629.
Cervical and Lumbar Disc Arthroplasty: A Review of Current Implant Design and Outcomes – PMC
Compared safety profiles, range of motion (ROM), pain reduction (VAS), and disability scores (ODI) between single-level versus multi-level lumbar artificial disc replacements.
Citation: Schätz C, Ritter-Lang K, Gössel L, et al. Comparison of Single-Level and Multiple-Level Outcomes of Total Disc Arthroplasty: 24-Month Results. International Journal of Spine Surgery (IJSS), 2015; 9: 14
Long-term outcomes following lumbar total disc replacement with M6-L – PMC
Evaluated 24-month clinical outcomes, restoration of intervertebral disc height, and segment lordosis in lumbar degenerative disc disease treated with the M6-L prosthesis.